1000 Mar Walt Dr

Ft Walton Beach 32547 · Institutional

According to permitsearch.us records (updated 2026-08-07), 1000 Mar Walt Dr, Ft Walton Beach, FL 32547 has 191 permits on file.

The most recent permit on file is a 2026 mechanical trade permit trade permit permit (status: Issued).

records updated 2026-08-07

Year built
1973
Building area
423,335 ft²
Use
Institutional

Source: public property records

Permit history

4/2/2026Mechanical Trade Permit Trade Permit · • Selective demolition as shown on drawings is included • Furnish and install (1) Ductless Split System as scheduled • Furnish and install HVAC refrigerant piping as shown on drawings • Furnish and install (1) Roof Mounted Refrigerant Pipe Curb per Key Note 4 on drawing M101 • Furnish and install (1) NOA Rated Condensing Unit Stand per Key Note 5 on drawing M101 • Furnish and install (1) New Fire Damper as shown on drawings • Inspect (2) Existing Fire Dampers and repair as necessary per Key Note 1 on drawing M101 • Furnish and install air duct systems and devices as shown on drawings • Test and Balance by Dynamic Analysis, Inc. is included as specified on M301 • *Controls by Johnson Controls, Inc. (JCI) are included as specified on M301 BUILDING PERMIT BLDC-0226-0296Issued
1/28/2026Mechanical Trade Permit Trade Permit · NOC ON FILE WITH MASTER - EN BLDC-1125-0203 HVAC Scope of Work: • Selective demolition as shown on drawings is included • Furnish and install air duct systems with insulation as shown on drawings • Furnish and install air devices as shown on drawings • Test and Balance is included • Controls work by Johnson Controls (JCI) is included as specifiedFinalized
12/18/2025Commercial General Repair & Remodel General Repair & Remodel · Interior imaging room modification and equipment change out. Interior work only. Survey not required. FD approval on file. NOC is required. cadFinalized
10/1/2025Commercial Re-Roof Re-Roof · COMMERCIAL_PRIVATE HOSPITALS. New roof for HCA Hospital. Noc on file. MASTER #555484-RBO-2024. kwFinalized
5/13/2025Gas Trade Permit Trade Permit · *Verified in Eden (569773-GAS-2025) 04/27/26 -ER* Had to mark contractor as owner/builder due to being expired. HCA EPSS UPGRADES - NOC ON MASTER - GAS LINE TO GENERATOR - RMMExpired
5/13/2025Mechanical Trade Permit Trade Permit · *Verified in Eden (569772-MEC-2025) 04/20/2026 -ER* Marked contractor as owner/builder due to being expired. HCA EPSS UPGRADES - REPLACING MINI SPLIT - NOC ON MASTER - RMMIssued
4/20/2025Development Permit Development Permit · Vertical Expansion creating a 3rd & 4th Floor for the FWB Medical Center. LA *DO issued 5/22/22* MLMFinalized
2/17/2025Development Permit Development Permit · 7,550 SF attached emergency room addition. MM *DO issued 2/2/17* MMFinalized
2/17/2025Development Permit Development Permit · 131,801 SF, 4 level parking garage for the use of the existing medical facility (from the existing 156 standard parking spaces to 404 standard parking spaces and 11 HC accessible spaces). MM *DO issued 4/11/17* MMFinalized
2/11/2025Electrical Commercial Trade Sub-Permit Trade Sub-Permit · 2/23/2026: Extension given to match master permit. 3/25/25 Extension granted from 3/29/25 50 2/29/25 per P.A. cad COMMERCIAL - INTERIOR REMODEL - NOC ON MASTER - RMMIssued
2/3/2025Development Permit Development Permit · 4,177 SF, 1 story detached building addition for Behavioral Health Emergency Department - Observation Unit at FWB Medical Center. MM *DO issued on 4/3/16. MMFinalized
9/30/2024Remodel/Build Out Permit Remodel/Build Out Permit · Changed expiration date to 2/27/26, same as EDEN. cad 9/19/25 Reroof Permit #BLDC-0925-0140 3/25/25 Extension granted from 3/29/25 50 2/29/25 per P.A. cad ADDENDUM 12-31-24 RMM EPSS Upgrades. Walls, MEP's Fire sprinkler, masonry. FD approval on file. All internal no survey required. cad 12-16-24 NOC on file. cadIssued
9/12/2023Mechanical Trade Permit Trade Stand Alone · Floors 3, 4 and rooftop mechanical penthouse 2 Story ICU/CCU Tower vertical expansion to the existing 2 story ICU -OWNER IS USING PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-by $100 2 Story ICU/CCU Tower Addition to the existing 2 story ICU tower under construction. Floors 3, 4 and rooftop mechanical penthouse-OWNER IS USING PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-Tina 7-29-2022 (Plan review reduced by $4,892.19-Inspections reduced by $2,000 bldg permit fee -TOTAL Reduction $6,892.19Finalized
9/11/2023Plumbing Trade Permit Trade Stand Alone · Floors 3, 4 and rooftop mechanical penthouse 2 Story ICU/CCU Tower vertical expansion to the existing 2 story ICU -OWNER IS USING PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-by $100Finalized
8/16/2023Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Floors 3, 4 and rooftop mechanical penthouse 2 Story ICU/CCU Tower vertical expansion to the existing 2 story ICU PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-Tina by $100Finalized
8/2/2023Fire Sprinkler System Fire Sprinkler System · Install 475 Sprinkler Heads. cad 1-9-23 AKA Vertical Expansion Project. cad 2 Story ICU/CCU Tower Addition to the existing 2 story ICU tower under construction. Floors 3, 4 and rooftop mechanical penthouse-OWNER IS USING PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-Tina 7-29-2022 (Plan review reduced by $4,892.19-Inspections reduced by $2,000 bldg permit fee -TOTAL Reduction $6,892.19 Finalized
7/3/2023Electrical Commercial Trade Sub-Permit Trade Sub-Permit · FWB Medical Center. 2nd Floor LDR Renovation.Expired
6/14/2023Com Burglar/Fire Alarm Com Burglar/Fire Alarm · GM DATA Electrical and fire alarm only, work associated with vertical expansion of ICU tower, adding 3rd floor patient rooms and 4th floor shel space NOC not reqFinalized
6/5/2023Plumbing Trade Permit Trade Permit · 12-22 inspection is for room 252 12-13-23 inspection is for rooms 250 and 251 - CALL Erin Hodges 407-460-7943 30 mins out for entry. Plumbing for hospital maternity ward re-model.Expired
11/21/2022Fire Sprinkler System Fire Sprinkler System · Fire Sprinkler - 19 Heads. NOC on file w/master. FD approval attached. cad Re-model of X-ray 1 and 2; Fort Walton Beach Hospital. NOC and Affidavit of Architect required.Finalized
9/30/2022Mechanical Trade Permit Trade Permit · Replacing Air Handler Unit #34. NOC requiredFinalized
9/8/2022Mechanical Trade Permit Trade Permit · Re-model of X-ray 1 and 2; Fort Walton Beach Hospital. 4 Daikin Ceiling cassette fan coil units & duct modificationsFinalized
8/19/2022Building Commercial - Addition Addition · 1-9-23 AKA Vertical Expansion Project. cad 2 Story ICU/CCU Tower Addition to the existing 2 story ICU tower under construction. Floors 3, 4 and rooftop mechanical penthouse-OWNER IS USING PRIVATE PROVIDER FOR CONSTRUCTION PLANS & INSPECTIONS-PERMIT PRICE REDUCED-Tina 7-29-2022 (Plan review reduced by $4,892.19-Inspections reduced by $2,000 bldg permit fee -TOTAL Reduction $6,892.19Finalized
8/9/2022Remodel/Build Out Permit Remodel/Build Out Permit · -paid rr fee 1 20 23 el 1-19-23 Owes $50 rr fee for failed plumbing stack out. cad Contact Danny Keene 850-375-5520 Re-model of X-ray 1 and 2; Fort Walton Beach Hospital. NOC and Affidavit of Architect required.Finalized
8/4/2022Commercial Demolition Commercial · Demolition of X-Ray 1 and 2 FWB Hospital to prepare for rennovation. chm NOC requiredFinalized
5/11/2022Mechanical Trade Permit Trade Stand Alone · Please call 30 min prior to inspection AJ 727-423-0437 - Installation of a four compartment walk in coller/freezer combo. 6.7 tons. NOC on file w/master. cadFinalized
5/18/2021Mechanical Trade Permit Trade Stand Alone · Tower A - 170 Ton hvac, adding 3 air handlersExpired
5/18/2021Mechanical Trade Permit Trade Stand Alone · addition of Chiller and blower coil unitExpired
5/18/2021Mechanical Trade Permit Trade Stand Alone · Connector B - HVAC - adding 1 air handler and 1 heat pumpExpired
5/18/2021Mechanical Trade Permit Trade Stand Alone · Kitchen Adding 1 Air Handler - 3 mau'sFinalized
4/6/2021Mechanical Trade Permit Trade Stand Alone · Addition of chiller and Blower Coil UnitExpired
4/6/2021Plumbing Trade Permit Trade Stand Alone · 1 floor drain, 2 water connection plumbing office located in peach bldg. @ muster pt. 2 unit c. RANDY SPENCER 9126012734Finalized
1/22/2020Fire Sprinkler System Fire Sprinkler System · 30 Sprinkler heads NOC on file. 11-13-19 chm **Requesting AM inspection on 1.16.2020 for steel, if possible.** - ***Please call Lee @ 850-384-0513 for access to inspection area*** Interior remodel to pharmacy USP 800 Compliance. NOC is required prior to insepctions Interior only trades will pull own perm. ***Need AFF or Arch before selling permit***cadExpired
12/4/2019Mechanical Trade Permit Trade Permit · duct modification and installing 1 14ton roof top package unit and 2 exhaust fans NOC on file. 11-13-19 chm Interior remodel to pharmacy USP 800 Compliance. NOC is required prior to insepctions Interior only trades will pull own perm. ***Need AFF or Arch before selling permit***cadFinalized
5/16/2019Fire Sprinkler System Fire Sprinkler System · Fire Sprinkler System - 50 Additional Nozzles. FWB MEDICAL CENTER - ED(EMERGENCY DEPARTMENT)RENOVATIONS 2-1-17 JE Dunn brought the checks in and they are in the safe. cad 2-3-17 Water and Sewer letter is on file. cad 2-28-18 fire alarm permit is tied to 409276-cis-2017 scope of work is the same.vc poc--brandon-850-849-7601Finalized
4/4/2018Remodel/Build Out Permit Remodel/Build Out Permit · FWB MEDICAL CENTER - noc not required. fix handrailsFinalized
9/28/2017Com Burglar/Fire Alarm Com Burglar/Fire Alarm · FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. FIRE ALARMSFinalized
9/19/2017Com Burglar/Fire Alarm Com Burglar/Fire Alarm · ***Paid to reinstate permit and order finals for CO*** FWB MEDICAL CENTER - ED(EMERGENCY DEPARTMENT)RENOVATIONS 2 poc--brandon-850-849-7601 FIRE ALARM SYSTEM this covers the remodel and the new addition.Finalized
9/5/2017Underground Utilites Underground Utilities · FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. FIRE LINE ONLY*****JOSE 352-978-1994 Please call so he can be on site for inspection***** 8-31-17 permit paid for. needs to be routed and have someone from Wayne Fire to sign for. vickyFinalized
8/29/2017Mechanical Trade Permit Trade Stand Alone · FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. Installing a 1 ton mini split system with electric unit heater mounted in the electrical room. NOC is on file w/master. cadFinalized
8/14/2017Fire Sprinkler System Fire Sprinkler System · ***Paid fees to reinstate permit and order finals for CO*** FWB MEDICAL CENTER - ED( EMERGENCY DEPARTMENT) EXPANSION WITH HELIPORT ON ROOF. FIRE SPRINKLER SYSTEM 225 HEADSExpired
8/3/2017Fire Sprinkler System Fire Sprinkler System · FIRE SPRINKLER SYSTEM 795 HEADSS. FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. PRECAST 1 GROUND AND 3 ELEVATOR LEVELSFinalized
7/14/2017Underground Utilites Underground Utilities · FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. Underground utilities - Underground Fire Line by others.Finalized
4/24/2017Commercial New Construction New Construction · FT. WALTON BEACH MEDICAL CENTER COMMERICAL PARKING GARAGE. PRECAST 1 GROUND AND 3 ELEVATOR LEVELS, NOC REQUIRED. CERTIFIED FOUNDATION SURVEY REQUIRED BEFORE VERTICAL CONSTRUCTION. NO PLUMBING TO BE DONE 4-24-17 NOC is on file. cadFinalized
2/3/2017Commercial New Construction New Construction · ***Fees were paid to reinstate the master permit and all subs, and to cover all reinspection fees due*** ***NEEDS TO REINSTATE MASTER AND ALL SUB PERMITS AND PAY FOR FWB MEDICAL CENTER - ED( EMERGENCY DEPARTMENT) EXPANSION WITH HELIPORT ON ROOF 2-1-17 JE Dunn brought the checks in and they are in the safe. cadExpired
11/15/2016Fire Sprinkler System Fire Sprinkler System · interior remodel to Emergency room department CT and xray renovations Fire sprinkler 14 headsFinalized
11/1/2016Com Burglar/Fire Alarm Com Burglar/Fire Alarm · addition for FWBMC Psych Wing FIRE ALARMFinalized
7/11/2016Remodel/Build Out Permit Remodel/Build Out Permit · EXPIRED PERMIT: 2/3/20 interior remodel to Emergency room department CT and xray renovations 2-22-18 $35 reinsp due. emailed contractor. cadFinalized
6/20/2016Fire Sprinkler System Fire Sprinkler System · addition for FWBMC Psych Wing. noc required. certified foundation survey required before vertical constructionFinalized
5/12/2016Building Commercial - Addition Addition · addition for FWBMC Psych Wing. noc required. certified foundation survey required before vertical constructionLExpired
1/25/2016Remodel/Build Out Permit Remodel/Build Out Permit · hospital. repairs to wall at emergency room entrance. noc on fileExpired
11/6/2015Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Phase I renovation to Cath Lab @ the existing Ft Walton Beach Medical Center adding 10 circuits up to 60 amps and 2 circuits up to 800 amps A/C PREP HOLD FOR 12-4-15Expired
7/31/2015Mechanical Trade Permit Trade Stand Alone · Phase I renovation to Cath Lab @ the existing Ft Walton Beach Medical Center HVACExpired
7/31/2015Fire Sprinkler System Fire Sprinkler System · Phase I renovation to Cath Lab @ the existing Ft Walton Beach Medical CenterExpired
7/2/2015Remodel/Build Out Permit Remodel/Build Out Permit · Phase I renovation to Cath Lab @ the existing Ft Walton Beach Medical CenterExpired
5/14/2015Commercial Accessory Structure Accessory Structure · walkway for mobile cath lab. noc required before inspectionsFinalized
4/6/2015Development Permit Development Permit · Proposed canopy extension. On hold per the engineer due to some revisions required by the client. 2/24/15 Revised plan submitted per the applicant's request. MM *DO issued 4/3/15* MMFinalized
3/26/2015Commercial Accessory Structure Accessory Structure · FWB MEDICAL CENTER. canopy replacement for emergency room/trama center. noc required before inspectionsFinalized
1/23/2015Board of Adjustments Board of Adjustments · Variance request from Section 6.05.021 Perimeter Requirements for the proposed canopy extension from 10' to 0. *12/10/14 BOA approval on the variance request as submitted* MMFinalized
12/15/2014Fire Sprinkler System Fire Sprinkler System · FWB MEDICAL CENTER. remodel of trama center. noc required before inspectionsExpired
12/11/2014Remodel/Build Out Permit Remodel/Build Out Permit · FWB MEDICAL CENTER. remodel of trama center. noc required before inspection Expired
10/31/2014Fire Sprinkler System Fire Sprinkler System · 4th floor office @ Ft Walton Beach Medical CenterFinalized
10/29/2014Mechanical Trade Permit Trade Permit · 4th floor office @ Ft Walton Beach Medical Center installing 2 grills and duct modifications only Contract on fileFinalized
10/28/2014Electrical Commercial Trade Sub-Permit Trade Sub-Permit · 4th floor office @ Ft Walton Beach Medical CenterFinalized
10/17/2014Remodel/Build Out Permit Remodel/Build Out Permit · 4th floor office @ Ft Walton Beach Medical CenterFinalized
9/26/2014Fire Sprinkler System Fire Sprinkler System · FWB MEDICAL CENTER. 3RD FLOOR RENOVATION TO CORRIDORS AND FINISH UPGRADE.noc on fileFinalized
7/15/2014Remodel/Build Out Permit Remodel/Build Out Permit · FWB MEDICAL CENTER. 3RD FLOOR RENOVATION TO CORRIDORS AND FINISH UPGRADE.noc on fileFinalized
6/3/2014Com Burglar/Fire Alarm Com Burglar/Fire Alarm · FWB Medical Center Psychiatric Wing renovation - fire alarmFinalized
5/23/2014Fire Sprinkler System Fire Sprinkler System · FWB Medical Center Psychiatric Wing renovation - fire sprinkler Finalized
12/16/2013Mechanical Trade Permit Trade Permit · FWB Medical Center Psychiatric Wing renovation - NOC on file Mechanical permit - install (1) fan coil unit, (1) roof mounted exhaust fan and duct modificationsFinalized
12/4/2013Remodel/Build Out Permit Remodel/Build Out Permit · FWB Medical Center Psychiatric Wing renovation - NOC on file CONT # 2329954Finalized
7/19/2013Fire Sprinkler System Fire Sprinkler System · FWB Medical Center MRI & Nuclear Medicine renovation change out six heads in nuclear med center. Purl approved work to be done before permit was issued since system was being taken down. 7/2/13 Finalized
6/18/2013Plumbing Trade Permit Trade Permit · FWB MEDICAL CENTER. 2ND FLOOR ICU suite renovations. noc required before inspections.Finalized
6/18/2013Electrical Commercial Trade Sub-Permit Trade Sub-Permit · FWB MEDICAL CENTER. 2ND FLOOR ICU suite renovations. noc required before inspections.Finalized
6/17/2013Mechanical Trade Permit Trade Stand Alone · FWB MEDICAL CENTER. 2ND FLOOR ICU suite renovations. DUCT MODIFICATIONS ONLY - issued by sheilaFinalized
6/14/2013Remodel/Build Out Permit Remodel/Build Out Permit · FWB MEDICAL CENTER. 2ND FLOOR ICU suite renovations. noc required before inspections.Finalized
6/3/2013Remodel/Build Out Permit Remodel/Build Out Permit · FWB Medical Center MRI & Nuclear Medicine renovation - NOC on file GC-DAN-390-6007 Finalized
8/8/2012Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior renovations to 2nd floor labor & delivery suite at the existing Ft. Walton Bch Medical CenterFinalized
8/6/2012Gas Trade Permit Trade Stand Alone · Interior renovations to 2nd floor labor & delivery suite at the existing Ft. Walton Bch Medical Center nine med gas outletsFinalized
8/6/2012Plumbing Trade Permit Trade Stand Alone · Interior renovations to 2nd floor labor & delivery suite at the existing Ft. Walton Bch Medical CenterFinalized
8/2/2012Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations to 2nd floor labor & delivery suite at the existing Ft. Walton Bch Medical CenterFinalized
8/2/2012Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovation for Hyperbaric Oxygen Therapy Suite. noc required before inspections NOC on fileExpired
6/21/2012Remodel/Build Out Permit Remodel/Build Out Permit · SPECIAL PROCEDURES LAB/XRAY 1ST FLOOR remodel of space imaging equipment replacement with minor mp&e system modifications. noc required before inspections NOC on fileFinalized
4/10/2012Mechanical Trade Permit Trade Stand Alone · FORT WALTON BEACH MEDICAL CENTER. 3rd floor remodel to Dialysis Rm. NOC exp 3-16-13 - REPLACING GRILLESFinalized
4/6/2012Electrical Commercial Trade Sub-Permit Trade Sub-Permit · FORT WALTON BEACH MEDICAL CENTER. 3rd floor remodel to Dialysis Rm. NOC exp 3-16-13Finalized
4/6/2012Plumbing Trade Permit Trade Permit · FORT WALTON BEACH MEDICAL CENTER. 3rd floor remodel to Dialysis Rm. NOC exp 3-16-13Finalized
3/26/2012Remodel/Build Out Permit Remodel/Build Out Permit · FORT WALTON BEACH MEDICAL CENTER. 3rd floor remodel to Dialysis Rm. NOC exp 3-16-13-. $35 rr fee pd 6-6-12Finalized
2/8/2012Mechanical Trade Permit Trade Stand Alone · Tropical Smoothie Cafe in the existing FWB Medical Center-Rework existing duct work & install temp negative air machineFinalized
2/8/2012Fire Sprinkler System Fire Sprinkler System · Tropical Smoothie Cafe in the existing FWB Medical Center-Fire Sprinkler Remodel 10 headsFinalized
1/31/2012Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Tropical Smoothie Cafe in the existing FWB Medical Center installing 175 amp sub panel and circuits.Finalized
1/27/2012Plumbing Trade Permit Trade Stand Alone · Tropical Smoothie Cafe in the existing FWB Medical CenterFinalized
11/9/2011Fire Sprinkler System Fire Sprinkler System · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. Fire Sprinkler relocationsFinalized
10/18/2011Mechanical Trade Permit Trade Stand Alone · Fort Walton Beach Medical Center. Replacement of 64 existing chilled water fan coil units on 2nd, 3rd and 4th floors. NOC exp 11-2-12Finalized
8/23/2011Remodel/Build Out Permit Remodel/Build Out Permit · Fort Walton Beach Medical Center Bronchoscopy Renovation - NOC required prior to inspectionFinalized
8/1/2011General Building Pemit General Building Permit · Reroof a portion of the existing hospital over the ER area approx 12,700 sf - Notice of Commencement required prior to inspectionExpired
3/15/2011Com Burglar/Fire Alarm Com Burglar/Fire Alarm · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. NOC required before inspections. FIRE ALARMFinalized
2/24/2011Plumbing Trade Permit Trade Permit · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. NOC required before inspections.Finalized
2/15/2011Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Remodel 1st floor FWB Medical Center-Admin area rooms 103-119 & 123 - See scope of work in file GREENHUT--Bill 232-7481 RandyExpired
2/9/2011Mechanical Trade Permit Trade Permit · taking down existing grills to clean them and relocating them in new ceiling.Finalized
2/9/2011Electrical Commercial Trade Sub-Permit Trade Sub-Permit · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. NOC required before inspections. RANDY 259-7918Finalized
12/8/2010Remodel/Build Out Permit Remodel/Build Out Permit · Remodel 1st floor FWB Medical Center-Admin & Physician support area i.e., Physician lounge & Dining, Visitor lounge, staff dining-NOC on fileFinalized
12/3/2010Mechanical Trade Permit Trade Stand Alone · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. *************6 FAN COIL UNITS WITH GRILLESFinalized
11/10/2010Remodel/Build Out Permit Remodel/Build Out Permit · FORT WALTON BEACH MEDICAL CENTER. 4TH floor renovations. NOC required before inspections.Finalized
11/9/2010Com Burglar/Fire Alarm Com Burglar/Fire Alarm · Fire Alarm for cafeteria area in existing FWB Medical CenterExpired
10/18/2010Electrical Commercial Trade Sub-Permit Trade Sub-Permit · remodel 1st floor of the existing Ft. Walton Beach Medical Center, new walls, doors, flooring, casework, electrical mech and plumb. NOC required before inspectionsFinalized
2/17/2010Remodel/Build Out Permit Remodel/Build Out Permit · Hospital Emergency dept and Mental Health Upgrade remodel to include flooring frames and doors, plumbing, HVAC, Ele, Fencing and paint. NOC required before inspectionFinalized
12/16/2009Commercial Accessory Structure Accessory Structure · Closure of a 1,000 gallon underground fuel tank - NOC expires 12-16-10Finalized
1/15/2009Eden Development Order Development Order · Proposed driveway relocation, will require TRC review/bmhFinalized
5/13/2008Plumbing Trade Permit Trade Stand Alone · Replace fixtures in Roms 102, 121 & the labor & deliver room 3 at Ft. Walton Beach Medical Center PERMIT EXTENDED UNTIL JULY 15, 2009 PER BILL LEMASTERFinalized
4/24/2008Remodel/Build Out Permit Remodel/Build Out Permit · Remodel of existing hospital Cath Lab. NOC required before inspections. NOC expires 05-06-2009 NEED fire dept approval on finalFinalized
4/15/2008Electrical Commercial Trade Sub-Permit Trade Sub-Permit · ADA Remediation of the Ft. Walton Beach Hospital - issued by sheila PERMIT EXTENDED UNTIL JULY 15, 2009Finalized
2/28/2008Remodel/Build Out Permit Remodel/Build Out Permit · ADA Remediation of the Ft. Walton Beach Hospital PERMIT EXTENDED UNTIL JULY 15, 2009 PER BILL LEMASTERFinalized
12/10/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior remodel of 2nd floor Nurses Station-Third phase of FWB Medical Center Finaled 2008 - Backflow, fire deptFinalized
11/7/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior remodel of 2nd floor lobby Third phase. NOC required before inspections. Finaled 2008 - Need backflow, fire dpt aff of archFinalized
9/13/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior remodel of 2nd floor lobby. NOC required before inspections. Bldg Final 2007 - Need Fire Department ApprovalFinalized
9/13/2007Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior remodel of 2nd floor lobby. NOC required before inspections. Finaled 2007Finalized
8/22/2007Com Burglar/Fire Alarm Com Burglar/Fire Alarm · ***FIRE ALARM***Finalized
8/13/2007Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior renovations for 2nd floor finish upgrades - Elevator Lobby & Corridor Fort Walton Beach Medical CenterFinalized
7/26/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations for 2nd floor finish upgrades - Elevator Lobby & Corridor Fort Walton Beach Medical Center Finaled 2007 - Need Fire Dept ApprovalFinalized
7/23/2007Fire Sprinkler System Fire Sprinkler System · Interior renovations to Electro-Physiology (EP) Room @ Ft. Walton Beach Medical Center fire sprinkler. moving heads not installing new ones.Finalized
7/5/2007Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior renovations for Nursery 2nd Floor, Notice of Commencement on file exp 3/6/08.Finalized
5/29/2007Fire Sprinkler System Fire Sprinkler System · Interior renovations for Nursery 2nd Floor, Notice of Commencement on file exp 3/6/08.Finalized
5/2/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations for Nursery 2nd Floor, Notice of Commencement on file exp 3/6/08.Finalized
4/3/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior remodel of computer room @ the Ft. Walton Beach Medical Center "Technology Refresh"Finalized
4/3/2007Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior remodel of computer room @ the Ft. Walton Beach Medical Center "Technology Refresh" adding circuitsFinalized
3/6/2007Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations to Electro-Physiology (EP) Room @ Ft. Walton Beach Medical Center - Repermitted from 291436-CIN-2006Finalized
2/25/2005Plumbing Trade Permit Trade Stand Alone · Fort Walton Beach Medical Center. Renovation of Patient Care Area, Second Floor. 1000 SF. PLUMBING PERMITFinalized
2/23/2005Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Fort Walton Beach Medical Center. Renovation of Patient Care Area, Second Floor. 1000 SF. Notice of Commencement Required. Affidavit of Arch on File.Finalized
2/9/2005Remodel/Build Out Permit Remodel/Build Out Permit · Fort Walton Beach Medical Center. Renovation of Patient Care Area, Second Floor. 1000 SF. Notice of Commencement Required. Affidavit of Arch on File.Finalized
1/25/2005Com Burglar/Fire Alarm Com Burglar/Fire Alarm · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X.Finalized
9/27/2004Fire Sprinkler System Fire Sprinkler System · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X. Fire sprinklerFinalized
8/31/2004Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X.Finalized
8/3/2004Gas Trade Permit Trade Stand Alone · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X. 99 outlets for Medical GasFinalized
8/3/2004Plumbing Trade Permit Trade Stand Alone · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X.Finalized
7/29/2004Mechanical Trade Permit Trade Stand Alone · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X.Finalized
7/8/2004Remodel/Build Out Permit Remodel/Build Out Permit · Interior build out for the 4th floor of the Medical Center. NOC is required. Flood zone X.Finalized
12/12/2003Eden Development Order Development Order · Proposed Entrance expansion to the Open Heart Division, foundation survey not required/bmFinalized
4/17/2003Electrical Commercial Trade Sub-Permit Trade Sub-Permit · 3rd Floor Nurse Core Renovations to Fort Walton Medical CenterFinalized
4/10/2003Remodel/Build Out Permit Remodel/Build Out Permit · 3rd Floor Nurse Core Renovations to Fort Walton Medical CenterFinalized
3/4/2003Remodel/Build Out Permit Remodel/Build Out Permit · This is for the exterior to hospital to include aesthetic roofing, building 2 entrance canopy, paint EFEIFS installation system, and new front entranceFinalized
11/20/2002Plumbing Trade Permit Trade Stand Alone · Temporary Central Sterile for the 4th floor Shell addition @ Ft. Walton Medical CenterFinalized
11/20/2002Mechanical Trade Permit Trade Stand Alone · Temporary Central Sterile for the 4th floor Shell addition @ Ft. Walton Medical CenterFinalized
11/15/2002Remodel/Build Out Permit Remodel/Build Out Permit · Cath Lab Renovation @ Ft. Walton Medical CenterFinalized
11/15/2002Remodel/Build Out Permit Remodel/Build Out Permit · CT Scan/MRI @ Ft. Walton Medical CenterFinalized
11/15/2002Remodel/Build Out Permit Remodel/Build Out Permit · Temporary Central Sterile for the 4th floor Shell addition @ Ft. Walton Medical CenterFinalized
8/28/2002Eden Development Order Development Order · Vinyl Awning covering rear entrance west side of FWMC No survey required **Affidavit under 25000.00r already on file***Finalized
8/14/2002Fire Sprinkler System Fire Sprinkler System · 3 Rd Area SFinalized
7/25/2002Electrical Commercial Trade Sub-Permit Trade Sub-Permit · 4th floor addition 20,807 sq ft and 3,468 sq ft for a 5th floor Pentehouse (equipment room only), equipment room added 6/14/02 - bm - Shell Only- app by Earl E & Tom C to sell for the corridorFinalized
6/20/2002Eden Development Order Development Order · 4th floor addition 20,807 sq ft and 3,468 sq ft for a 5th floor Pentehouse (equipment room only), survey not required - equipment room added 6/14/02 - bm - Shell Only **See Conditions**Finalized
2/20/2002Fire Sprinkler System Fire Sprinkler System · Sprinkler System for Area S (4th Floor Addition) & D Area and Fire PumpFinalized
1/28/2002Pollutant Storage Tank Below Ground Below Ground · Installation of Fuel Oil Storage Tank & PipingFinalized
11/1/2001Gas Trade Permit Trade Stand Alone · This is for the renovationFinalized
11/1/2001Mechanical Trade Permit Trade Stand Alone · Proposed 67,103 square feet renovations & additions, Certified foundation survey required - bm This is for the addition only - See conditions for renovation permit - aseFinalized
10/30/2001Com Burglar/Fire Alarm Com Burglar/Fire Alarm · Proposed 67,103 square feet renovations & additions, Certified foundation survey required - bm This is for the addition only - See conditions for renovation permit - aseFinalized
10/30/2001Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Proposed 67,103 square feet renovations & additions, Certified foundation survey required - bm This is for the addition only - See conditions for renovation permit - aseFinalized
10/25/2001Remodel/Build Out Permit Remodel/Build Out Permit · Renovations to Fort Walton Medical Center This permit issue date is 10/25/01-tln (replaces permit #224619)Finalized
10/25/2001Eden Development Order Development Order · Certified foundation survey required, This is for the 3rd floor addition, 1 Story Surgery Addition, 1 story Outpatient Surgery Addition., & ICU, & Central Energy Plant Bldg.Finalized
8/16/2000Mechanical Trade Permit Trade Permit · New System for Ft. Walton Bch Medical Center/issued by jeanFinalized
Mechanical Trade Permit Trade Stand Alone · Change out air handler #6 at the Fort Walton Beach Medical Center **NOC is required** cancelled permit-see routing history-ae/almVoid
Remodel/Build Out Permit Remodel/Build Out Permit · *** 8 yr old permit abandoned by applicant -NEVER RECEIVED FD APPROVAL Tropical Smoothie Cafe in the existing FWB Medical CenterExpired
Remodel/Build Out Permit Remodel/Build Out Permit · *** 8 yr old permit abandoned by applicant -Express Care. Interior Renovation with no exterior work involved. NOC expires 8/3/12 Affidavit of Arch on file. - NEED FIRE DEPT APPROVALExpired
Remodel/Build Out Permit Remodel/Build Out Permit · Remodel 1st floor FWB Medical Center-Admin area rooms 103-119 & 123 - See scope of work in file - RESUBMITAL FEE DUE. Cancelled permit over 2 years old. cadVoid
Eden Development Order Development Order · Canceled permit see routing history-ase/tlnVoid
Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations to Electro-Physiology (EP) Room @ Ft. Walton Beach Medical Center Canceled permit see routing history-tlnVoid
Mechanical Trade Permit Trade Stand Alone · 12/16/2024: $50 RR fee due B4 closing out. Email sent. -MAM replace 3 air cooled chillers like for like Expired over 6 months old. Feb 12, 2025Expired
Residential Re-Roof Re-Roof · reroof. NOC required. this is for the lower section, N and J ony about 20,000 sq ft. Canceled permit - see routing history - ase/rlVoid
Remodel/Build Out Permit Remodel/Build Out Permit · remodel 1st floor of the FWB Medical Center-Admin, Physician lounge & Dining, Visitor lounge, staff dining - new walls, doors, flooring, casework, elec mech & plumb Canceled permit see routing-tlnVoid
Commercial Accessory Structure Accessory Structure · Wall mounted directional signs for the existing Fort Walton Beach Medical Center - NOC NOT required-Canceled permit see routing history-tlnVoid
Remodel/Build Out Permit Remodel/Build Out Permit · FWB Medical Center. 2nd Floor LDR Renovation. Aff of Arch and FD on file. NOC is required. Survey not required. cad Expired over 6 months old. Jun 22, 2024Expired
Plumbing Trade Permit Trade Stand Alone · Relocating exsisting water and sewer lines for FWMC cancelled permit-see routing history-ae/almVoid
Com Burglar/Fire Alarm Com Burglar/Fire Alarm · FWB Medical Center Psychiatric Wing renovation installing Burglar Alarm systemVoid
Com Burglar/Fire Alarm Com Burglar/Fire Alarm · Fort Walton Beach Medical Center - Fire Alarm Replacement. Aff or Arch is required prior to selling permit. Need Signature on Bldg Application. cad Expired over 6 months old. Apr 03, 2021Expired
Com Burglar/Fire Alarm Com Burglar/Fire Alarm · tie into existing fire alarms add more NOC on file. 11-13-19 chm Interior remodel to pharmacy USP 800 Compliance. NOC is required prior to insepctions Interior only trades will pull own perm. ***Need AFF or Arch before selling permit***cadExpired
Com Burglar/Fire Alarm Com Burglar/Fire Alarm · Expired, no activity in 6 months. Fire Alarm- NOC on file with master- jbExpired
Remodel/Build Out Permit Remodel/Build Out Permit · Interior renovations to Hybrid Operating Room (OR) Room @ Ft. Walton Beach Medical Center VOID NO INSP IN OVER A YEAR. vocVoid
Fire Sprinkler System Fire Sprinkler System · Fire Sprinkler for FWB Medical Energy Plant & area A & BVoid
Eden Development Order Development Order · 3rd story addition / Type II Canceled permit see routing history - ase/tlnVoid
Commercial Accessory Structure Accessory Structure · For 3rd Story AdditionHospital (Average) Type II Cancled permit see routing history - ase/tlnVoid
Plumbing Trade Permit Trade Stand Alone · Interior Renovations. CT Scan Suite. At final inspection, will need fire dept approval, original aff of arch, to receive CO. - plu permit issued by sheilaVoid
Mechanical Trade Permit Trade Permit · SEE ROUTING HISTORYVoid
Fire Sprinkler System Fire Sprinkler System · Interior renovations to Hybrid Operating Room (OR) Room @ Ft. Walton Beach Medical Center., Fire sprinkler relocating not adding.Void
Commercial Accessory Structure Accessory Structure · 800 sq ft. picnic pavillion. Open on four sides. No Certified Survey Required.Void
Remodel/Build Out Permit Remodel/Build Out Permit · NOC on file 5/26/22 chm Hospital Project: Electrophysilogy Equipment Replacement / Flooring Paint HVAC, Plumbing Electrical - noc required -ca Expired over 6 months old. Mar 26, 2023Expired
Remodel/Build Out Permit Remodel/Build Out Permit · Interior Renovations. CT Scan Suite. At final inspection, will need fire dept approval, original aff of arch, to receive CO.Void
Electrical Commercial Trade Sub-Permit Trade Sub-Permit · Interior Renovations. CT Scan Suite. At final inspection, will need fire dept approval, original aff of arch, to receive CO.Void
Commercial Accessory Structure Accessory Structure · 156 Sq Ft of Awning.Void
Mechanical Trade Permit Trade Stand Alone · NOC IS REQUIRED. 3-AIR HANDLERS***VOID NO INSPECTIONS CYC*** see routing historyVoid
Commercial Accessory Structure Accessory Structure · Expired, no activity in 6 months. 2-2-23 7-8-19 Need FD final approval. $50 RR fee due. cad Inspector please call Mike Clark at 850-393-6012 before insp. Mr. Clark will be at job site til Noon Monday. NOC received 2/12/19 chm ****Contractor needs to supply a site plan**** Installing a canopy over the walkway for the Central Energy Plant an independent structure located at the southwest corner of the hospital. NOC is required.Expired
Remodel/Build Out Permit Remodel/Build Out Permit · NOC on file. 11-13-19 chm **Requesting AM inspection on 1.16.2020 for steel, if possible.** - ***Please call Lee @ 850-384-0513 for access to inspection area*** Interior remodel to pharmacy USP 800 Compliance. NOC is required prior to insepctions Interior only trades will pull own perm. ***Need AFF or Arch before selling permit***cad Expired over 6 months old. Feb 26, 2021Expired
Burglar/Fire Alarm System Fire Alarm System · NOC on file. 11-13-19 chm **Requesting AM inspection on 1.16.2020 for steel, if possible.** - ***Please call Lee @ 850-384-0513 for access to inspection area*** Interior remodel to pharmacy USP 800 Compliance. NOC is required prior to insepctions Interior only trades will pull own perm. ***Need AFF or Arch before selling permit***cadExpired
Remodel/Build Out Permit Remodel/Build Out Permit · FWB MEDICAL CENTER - ED(EMERGENCY DEPARTMENT)RENOVATIONS 2-1-17 JE Dunn brought the checks in and they are in the safe. cad 2-3-17 Water and Sewer letter is on file. cad 2-28-18 fire alarm permit is tied to 409276-cis-2017 scope of work is the same.vc poc--brandon-850-849-7601 Expired over 6 months old. Dec 11, 2019Expired

A permit history reflects what was filed with the county; it is a record of filings, not an assessment of current condition.

Touring this house? Run a HouseRecon walkthrough →

Free · photos in, inspector questions out · HouseRecon by PermitSearch

Overview

This institutional at 1000 Mar Walt Dr was built in 1973. county records show 191 permit(s), most recently a mechanical trade permit trade permit in 2026.

Watch this address — free

We'll email you if a permit is filed on it.

Free. One email to confirm, then alerts only when a new permit record appears on file. Unsubscribe any time.

institutional property — the records above are public information provided for general reference.

Sources: county permit portals, public property records, FEMA, USGS, ASCE. Public-record information presented for general use · permitsearch.us is not affiliated with any government agency · © 2026